Configuring Frame Relay
Concentrating incoming calls onto Frame Relay
MAX 6000/3000 Network Configuration Guide Preliminary January 4, 2001 5-23
Examples of FR Direct connections
In the following example, the MAX forwards the data stream from two PPP dial-in hosts
across Frame Relay on the same DLCI interface, as shown in Figure 5-9:
Figure 5-9. Frame Relay Direct
The following parameters specify the DLCI interface to frswitch-1 in Figure 5-9:
Ethernet
Connections
frswitch-1
Name=frswitch-1
Active=Yes
Encaps=FR
IP options
LAN Adrs=10.10.10.10/24
Encaps options
FR Prof=fr-dte
DLCI=72
Following is a comparable RADIUS profile:
permconn-max-3 Password="ascend", User-Service=Dialout-Framed-User
User-Name="frswitch-1",
Framed-Protocol=FR,
Framed-Address=10.10.10.10,
Framed-Netmask=255.255.255.0,
Ascend-Route-IP=Route-IP-Yes,
Ascend-FR-DLCI=72,
Ascend-FR-Profile-Name="fr-dte"
Framed-Address (8) PPP caller’s IP address. As the MAX receives return packets for
many Frame Relay Direct connections on the same DLCI, it uses
this address to determine which PPP caller should receive the
return packets.
Framed-Netmask (9) A subnet mask for Framed-Address.
Attribute Value
DLCI 72
Caller-1
10.5.6.7/32
Caller-2
10.7.8.9/32
frswitch-1
10.10.10.10