Lucent-technologies 6000 Manual de usuario Pagina 275

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 586
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 274
Configuring Frame Relay
Configuring the MAX as a Frame Relay switch
MAX 6000/3000 Network Configuration Guide Preliminary January 4, 2001 5-27
Nailed Grp=111
Ethernet
Frame Relay
p130east
Name=p130east
Active=Yes
FR Type=DCE
Nailed Grp=222
The next set of parameters specifies the circuit between the two Frame Relay interfaces:
Ethernet
Connections
max6
Station=max6
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=max
DLCI=100
FR Circuit=frcir1
Ethernet
Connections
p130
Name=p130
Active=Yes
Encaps=FR-Cir
Encaps options
FR Prof=p130east
DLCI=200
FR Circuit=frcir1
Using RADIUS profiles
The following RADIUS frdlink pseudo-user profiles define the datalinks to the MAX and to
the Pipeline 130 (P130-East):
frdlink-max-21 Password="ascend", User-Service=Dialout-Framed-User
Ascend-FR-Profile-Name="max",
Ascend-Call-Type=Nailed,
Ascend-FR-Type=Ascend-FR-DCE,
Ascend-FR-Nailed-Grp=111
frdlink-max-22 Password="ascend", User-Service=Dialout-Framed-User
Ascend-FR-Profile-Name="p130east",
Ascend-Call-Type=Nailed,
Ascend-FR-Type=Ascend-FR-DCE,
Ascend-FR-Nailed-Grp=222
Vista de pagina 274
1 2 ... 270 271 272 273 274 275 276 277 278 279 280 ... 585 586

Comentarios a estos manuales

Sin comentarios