DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Administering ATM-PNC and ATM-CES
5-13Administering DEFINITY ECS
5
11. Set the
synchronization
Set the Synchronization Capable field to n (default).
NOTE:
Up to 44 boards may be designated
synchronization capable on R8r and 3 boards on
R8si, R8csi, R8c. If you enter y in this field when the
maximum number of boards has been designated,
the system returns:
Maximum number of Synchronization
Capable boards already administered
NOTE:
If this ATM trunk circuit pack is a synchronization
source, set the field to y. If you change the field to n
when the circuit pack is administered as a
synchronization source, the system returns:
Cannot remove synchronization source.
12. Administer the
signaling group
Typ e add signaling-group and press Enter. The Signaling
Group screen (Screen 3-3
) displays.
Set the following fields (tabbing goes vertically)
13. Set the group type Set the Group Type field to atm.
14. Type port address Type the D-channel (signaling channel) port address for
this new signaling group in
UUCSSppp
screen at (3-digits
required for port addresses). This address must match the
slot and port number on an ATM-Interface circuit pack.
15. Type a name Type a name in the Name field (15 alpha-numeric
characters).
16. Set VPI The Virtual Path Identifier (VPI) field is set to 0
and is not administrable.
Table 5-8. ATM-CES administration — Continued
Step Action Description
Continued on next page