Operation and Maintenance
5-22
9124-A2-LB20-00
March 2000
Table 5-10. PVC Connection Status (2 of 2)
Field What It IndicatesStatus
EDLCI 0 to 62 For multiplexed DLCIs only.
Identifies an individual link/
connection embedded within a
DLCI.
Status
Identifies whether the physical
interfaces, LMIs, and DLCIs are all
enabled and active for this PVC
connection.
Active
1
H The PVC is currently active.
Inactive H The PVC is inactive because:
Alarm conditions and network
and SLV communication
status indicate that data
cannot be successfully
passed.
The unit has disabled the
interface or frame relay link
due to internal operating
conventions.
Activation of an alternate
virtual circuit is not warranted;
that is, no alarm condition on
the primary destination link
has been detected.
Disabled H The PVC cannot be activated
and is essentially disabled as a
result of how the unit was
configured. Possible causes:
The physical interface at one
or both ends of the PVC is/are
disabled.
The frame relay link on one or
both ends of the PVC is/are
disabled.
Invalid H Some portion of the PVC
connection is not fully configured.
1
For the circuit to be active, both Source and Destination Statuses must be Active.